Buscar en
Ciência & Tecnologia dos Materiais
Toda la web
Inicio Ciência & Tecnologia dos Materiais Evaluation of mode I fracture toughness of cortical bone tissue in the RL crack ...
Journal Information
Vol. 26. Issue 2.
Pages 96-101 (July - December 2014)
Share
Share
Download PDF
More article options
Vol. 26. Issue 2.
Pages 96-101 (July - December 2014)
Full text access
Evaluation of mode I fracture toughness of cortical bone tissue in the RL crack propagation system
Visits
1743
F.A.M. Pereiraa, M.F.S.F. de Mourab,
Corresponding author
mfmoura@fe.up.pt

Corresponding author.
, N. Douradoa, J.J.L. Moraisa, M.I.R. Diasc
a CITAB/UTAD, Departamento de Engenharias, Quinta de Prados, 5001-801 Vila Real, Portugal
b Faculdade de Engenharia da Universidade do Porto, Departamento de Engenharia Mecânica, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
c UTAD, Departamento de Ciências Veterinárias, Quinta de Prados, 5001-801 Vila Real, Portugal
This item has received
Article information
Abstract

In this work the mode I fracture properties of bone tissue were determined for the RL propagation system. With this aim, Double Cantilever Beam (DCB) fracture tests were performed using specimens of cortical bone tissue harvested from bovine femurs with an age of approximately 8 months. In order to overcome the difficulty associated to the monitoring of crack length during propagation in the course of the test, the CBBM (Compliance Based Beam Method) was used. This method is based on beam theory and experimental specimen compliance, thus allowing the attainment of an equivalent crack length during the test. The results obtained reveal the existence of a plateau on the Resistance-curve, thus making possible to estimate with accuracy the critical strain energy release rate.

Keywords:
bone
fracture
mode I
double cantilever beam test.
Full text is only aviable in PDF
References
[1]
J.-Y. Rho, L. Kuhn-Spearing, P. Zioupos.
Med. Eng. Phys, 20 (1998), pp. 92-102
[2]
L.C. Junqueira, J. Carneiro “Histologia básica”. Guanabara Roogan, 7a ed, 611-018, 1990.
[3]
M. Dias, L. Costa, C. Viegas, H. Alves, M. Pires “O Tecido Ósseo Biologia da Cicatrização”. Série Didáctica. Ciências Aplicadas; 280, Universidade de Trás-os-Montes e Alto Douro, Vila Real, 2005.
[4]
M. Doblaré, J.M. García, M.J. Gómez.
Eng. Fract. Mech, 71 (2004), pp. 1809-1840
[5]
D.T. Reilly, A.H. Burstein.
J. Biomech, 8 (1975), pp. 393-405
[6]
J.D. Currey.
Bones: structure and mechanics.
Princeton University Press, (2002),
[7]
A. Bingbing, L. Yang, A. Dwayne, Z. Dongsheng.
J. Mech. Behav. Biomed, 4 (2011), pp. 983-992
[8]
P. Zioupos.
Mat. Sci. Eng. C-Mater, 6 (1998), pp. 33-40
[9]
D. Vashishth, K.E. Tanner, W. Bonfield.
J. Biomech, 33 (2000), pp. 1169-1174
[10]
Y.N. Yeni, T.L. Norman.
J. Biomed. Mater. Res. B, 51 (2000), pp. 504-509
[11]
R.K. Nalla, J.H. Kinney, R.O. Ritchie.
Nat. Mater, 2 (2003), pp. 164-168
[12]
C.L. Malik, S.M. Stover, R.B. Martin, J.C. Gibeling.
J Biomech, 36 (2003), pp. 191-198
[13]
D. Vashishth.
J. Biomech, 37 (2004), pp. 943-946
[14]
K.J. Koester, H.D. Barth, R.O. Ritchie.
J. Mech. Behav. Biomed, 4 (2011), pp. 1504-1513
[15]
P. Lucksanasombool, W.A.J. Higgs, R.J.E.D. Higgs, M.V. Swain.
Biomater, 22 (2001), pp. 3127-3132
[16]
A. Ural, D. Vashishth.
J. Biomech, 39 (2006), pp. 2974-2982
[17]
R.O. Ritchie, K.J. Koester, S. Ionova, W. Yao, N.E. Lane, J.W. Ager.
[18]
Q.D. Yang, B.N. Cox, R.K. Nalla, R.O. Ritchie.
[19]
B.N. Cox, Q. Yang.
Eng. Fract. Mech, 74 (2007), pp. 1079-1092
[20]
J.J.L. Morais, M.F.S.F. de Moura, F.A.M. Pereira, J. Xavier, N. Dourado, M.I.R. Dias, J.M.T. Azevedo.
J. Mech. Behav. Biomed, 3 (2010), pp. 446-453
[21]
A. Ural.
Proc Eng, 10 (2011), pp. 2827-2832
[22]
J. Yan, K.B. Clifton, J.J. Mecholsky, R.L. Reep.
J Biomech, 39 (2006), pp. 1066-1074
[23]
R. de Santis, P. Anderson, K.E. Tanner, L. Ambrosio, L. Nicolais, W. Bonfield, G.R. Davis.
J. Mater. Sci-Mater. M, 11 (2000), pp. 629-636
[24]
J.B. Phelps, G.B. Hubbard, X. Wang, C.M. Agrawal.
J. Biomed. Mater. Re.s A, 51 (2000), pp. 735-741
[25]
F.A.M. Pereira, J.J.L. Morais, M.F.S.F. de Moura, N. Dourado, M.I.R. Dias.
Eng. Fract. Mech, 96 (2012), pp. 724-736
[26]
M.F.S.F. de Moura, J.P.M. Gonçalves, A.T. Marques, P.M.S. Tavares de Castro.
J. Comp. Mater., 31 (1997), pp. 1462-1479
[27]
F.A.M. Pereira, J.J.L. Morais, N. Dourado, M.F.S.F. de Moura, M.I.R. Dias.
J. Mech. Behav. Biomed, 4 (2011), pp. 1764-1773
[28]
J. McCormack, S.M. Stover, J.C. Gibeling, D.P. Fyhrie.
Bone, 50 (2012), pp. 1275-1280
[29]
J.S. Nyman, A. Roy, X. Shen, R.L. Acuna, J.H. Tyler, X. Wang.
J. Biomech, 39 (2006), pp. 931-938
[30]
X. Wang, C.M. Agrawal.
[31]
M.E. Szabó, P.J. Thurner.
Article options
Tools
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos